J-SAP-TCSB5406 W Wireless Digital Manual Call Point (hereinafter referred to as the alarm button ) is suitable for installation in public places, factories and other environments. When a fire is manually confirmed, press the button on the alarm button, and the red light of the alarm button is always on. to the wireless communication technology transmits an alarm signal to the control panel, the control panel when the response should the alarm signal the alarm button enters a wait control panel reset state, an alarm button while the control panel displays the encoded information and an alarm sounds.
2.Main Characteristics
1 using the pressing structure design, alarm button press need to use special tools to reset ;
2 Adopting 470MHz wireless communication technology , without pre-buried wiring, convenient and quick engineering installation;
3 With battery low voltage detection function , it can reflect the battery power situation in time;
4 The use of microprocessor to realize signal processing and digital signal to communicate with the control panel, the work is stable and reliable, and has a good ability to suppress electromagnetic interference.
3.Main technical specifications
1.Battery Type: CR17450 3.0 V / 2400mAh Voltage range: 2 .7 ~ 3.3V
2.Operating Current: Monitor current ≤ 10 uA alarm current ≤ .19 m A
3. Indicator:
Fire light: red, not network when logging every 48s flash time, alarm always lightens
Fault light: yellow , flashes twice every 48s when the battery is under power, and periodically flashes when the communication fails after being connected to the network
Working light: green , flashing periodically when the communication is normal after entering the network
4 . Encoding: automatically allocated when the network control panel
5 . Communication: 470MHz FSK encoded two-way communication
6 . Communication distance: ≤50m
7. Transmitting power: <20dBm
8 . Reset: special key reset
9. Form of starting parts: reusable type
10 . Use of the environment:
Type: Indoor atmospheric pressure: 86kPa~106kPa
Temperature: -10ºC~+55ºC Relative humidity ≤95%, non-condensing
11 . Dimensions: 95 m m × 96 m m × 50 m m
12 . Shell materials and colors: the ABS , red color
13 . Weight: about . 19 0 G (with battery)
14 . Implementation of the standards:
GB 19880-2005 "manual fire alarm button "
XF 1151-2014 " General Requirements for Wireless Communication Function of Fire Alarm System "
4.Fault and Abnormal information processing and Regular Check
Failure phenomenon | reason | Solution |
The control panel has no status prompt after the device alarms | The device is not connected to the network | Restart the network operation |
Device networking is unsuccessful | Too far away from the control panel or interference sources nearby | Move the device near the control panel, reconnect to the network and remove the source of interference |
The device's red light is off | Low battery or no battery inserted | Replacement battery |